SHARP LC-60LE635 Service mode adjustments and factory resetting

SHARP LC-60LE635

ADJUSTMENT 
Entering and exiting the adjustment process mode
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) At the state TV is turned on, touch the power key for 5seconds.
NOTE: Picture will disappear when you touch the power key, but keep touching the power key.
3) When the center icon LED blinks, release your finger from the power key.
4) Next, touch the “POWER” key with the “VOL (-)” and “INPUT” key touching.
TV will turn on and the letter “<K>” appears on the screen.

ADJUSTMENT PROCEDURE

1. Adjustment method after PWB and/or IC replacement due to repair
The unit is set to the optimum at the time of shipment from the factory.
If any value should become improper or any adjustment is necessary due to the part replacement, make an adjustment according to the following procedure.
1. Procure the following units in order to replace the main unit.
MAIN UNIT: DKEYDF733FM55 (LC-60LE635E)
MAIN UNIT: DKEYDF733FM56 (LC-60LE836E)
MAIN UNIT: DKEYDF733FM57 (LC-60LE838E)
NOTE: [Caution when replacing IC (IC2001) in the main unit]
The above IC are Monitor microcomputer.
Before replacing the relevant part, procure the following parts in which the data have been rewritten.
IC2001 RH-iXD241WJNJQ Monitor microcomputer
NOTE: [Caution when replacing ICs (IC8401, IC3303) in the main unit]
When replacing either IC8401 or IC3302, exchange MAIN units for DKEYDF733FM55 (LC-60LE635E), DKEYDF733FM56 (LC-60LE636E)
DKEYDF733FM57 (LC-60LE638E).
Each part should not be individually exchanged.
IC8401 RH-iXD287WJQZQ Flash
IC3303 RH-iXD220WJQZQ Main CPU
NOTE: HDMI ROM Writing
After replacing IC1504, execute “HDMI EDID WRITE”.
Please execute it after checking MODEL NAME & INCH SIZE. are correct. If MODEL NAME & INCH SIZE. are not correct, set  The ROM data based on information of MODEL NAME & INCH SIZE.
1) Enter the process adjustment mode in TV.
2) Use the cursor keys (UP /DOWN ) and CH keys ( UP/DOWN ) of R/C to select the item [HDMI EDID WRITE].
3) It is completed with OK displayed.
2. After replacing the LCD panel or LCD control/MAIN UNIT, check MODEL NAME in the following procedure.
1) Enter the process adjustment mode in TV.
2) Use the cursor keys ( UP/DOWN ) and CH keys ( UP/ DOWN) of R/C to select the item [MODEL NAME].
3) Verify that the Model name is displayed.
4) If the Model name doesn’t match, select the values of the Model name with the VOL keys (+/-).
5) After selection in Step 4), press the OK key, and it is completed with OK displayed.
6) Use the cursor keys ( UP/DOWN ) and CH keys ( UP/ DOWN) of R/C to select the item [PANEL_SIZE].
7) Verify that the panel size is displayed.
8) If the size doesn’t match, select the values of the panel size with the VOL keys (+/-).
9) After selection in Step 8), press the OK key, and it is completed with OK displayed.
10)After setting [MODEL NAME] [PANEL_SIZE], unplug the AC power cord and plug it back in.
3. After replacing the LCD panel or LCD control PWB, adjust the VCOM in the following procedure.
1) Enter the process adjustment mode.
2) Use the cursor keys ( UP/ DOWN) and CH keys ( UP/DOWN ) of R/C to select the item [VCOM ADJ].
3) Press the OK key to verify that the adjustment pattern is displayed.
4) Use VOL keys (+/-) of R/C to adjust the flicker in the center of the screen to minimum.
5) When the optimal state is achieved in Step 4), press the OK key to turn the pattern to OFF.
Special features
1. NORMAL STANDBY CAUSE (Page 1/20)
Display of a cause (code) of the last standby.
The cause of the last standby is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
2. EEP SAVE (Page 24/20)
Storage of EEP adjustment value.
3. EEP RECOVER (Page 20/20)
Retrieval of EEP adjustment value from storage area.
4. MONITOR ERR CAUSE (Page 1/20)
Display of a cause (code) of Error from Monitor microcomputer.
The cause of Error is recorded in EEPROM whenever it is possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
1) This displays Error code and time when the error occurred.
The latest error is displayed on “1)”.
The error that happens ahead of “1)” is displayed on “2)”.
2) The character depends on the way how to acquire Time Information.
T: Time is acquired from digital broadcasting
This doesn’t contain “Time offset” which is considered a time difference and Daylight-Saving Time, etc. ...
U: Time is acquired from analog broadcasting (teletext)
B: Accumulation time of Backlight
In the case that Time information cannot be acquired, “B” is displayed.
Lamp Error detection
Function
This LCD color TV set incorporates a Lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some reason, the following will result.
1) The power is interrupted in about 500ms after it is turned on.
(A central icon on the front of the TV flash on and off.: ON for 400ms and OFF for 1600ms.)
2) If the above phenomenon 1) occurs 5 times, it becomes impossible to turn on the power.
(A central icon keep flashing on/off.)
Measures
1) Set the lamp error detection to OFF
Enter the adjustment process mode, referring to “2. Entering and exiting the adjustment process mode”. The adjustment process mode can ignore “5 times count”, so If the above phenomenon 1) occurs 1~4 times, the lamp will go out. If Lamp Error detection pin [4pin of PD: P9602/19pin of IC2001] is “High” by a trouble with the lamp and lamp circuit, it can boot-up by the adjustment process mode.
Please execute “Lamp Error detection off-mode”.
Unplug the AC power cord of running TV set to force off the power.
While holding down the “VOL (-)” and “CH (UP )” keys on the set at once, touch the power supply key on the set.
After a central icon flash off, separate the fingers from key on the set.
Then, you can check the operation to see if the lamp and lamp circuit are in trouble. If you fail boot-up, retry the procedure.
Resetting the lamp error count
After the lamp and lamp circuit are improved from a trouble, reset the lamp error count.
(Because the power cannot be turned on, if a lamp error is detected 5 consecutive times.)
a) Enter the adjustment process mode,
b) Using the cursor ( UP/DOWN ) key, move to the cursor to [LAMP ERROR RESET], Line 8 on adjustment process mode service page 2/20.
c) With the cursor ( LEFT/ RIGHT) keys, select the [LAMP ERROR RESET] value.
Finally press the cursor (OK)., the count is reset.
Check LAMP ERROR Count on adjustment process mode Page 2/20.
Copy Mode
1. Starting the Copy Mode
There are two following ways to display the Copy Mode setting screen.
1) Method of needing password
a) Turn off the power, and turn it on again, pressing the “CHANNEL UP” and “Volume UP” keys of the main unit at the same time.
Please separate the finger from the power supply key when boot-up is confirmed with lighting of a central icon etc.
After a while, value of Enter password appears on the screen.
b) Display the Pass Word input screen.
Operation procedure
# The initial input position is the digit at the left end.
# For the numeric keys “0” to “9” of R/C, key input is accepted.
Input of the other keys is prohibited.
# Change “—” to “ ” by inputting the numeric key at the input position, and shift the input position rightward one digit.
# When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word “3” “6” “9”, it shifts to the Copy Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Copy Mode Setting screen
There is following way to exit the Copy Mode setting screen.
# Turn off the power. (Unplug the AC power cord from the outlet to forcibly turn off the power.)
Factory settings
[Factory setting with adjustment process mode]
# Enter the adjustment process mode.
# Move the cursor to [INDUSTRY INIT] on page 2/20.
3 Use the R/C key to select a region from [EUROPE/RUSSIA/SWEDEN] and press the [OK] key.
3 “EXECUTING” display appears.
3 After a while, “SUCCESS” display appears, the setting is completed.

When succeeding: Background color (green) When failing: Background color (red)
Upgrading the software
1. Turn on the AC power.
2. Insert the upgrading USB flash memory for upgrade into the service slot.
(After a while, an external input changes into USB automatically.)
3. Use the Menu button and cursor keys (LEFT / RIGHT/UP / DOWN), Ch keys (UP / DOWN) of R/C or on the set to select Menu - Setup - Information - Software update
- USB update on OSD menu.
4. The message (Insert the USB memory device contains the software update file) shows up.
Push OK when if there is no problem.