PANASONIC DMP-B100EB PORTABLE BLU RAY PLAYER SERVICE MODE FIRMWARE UPDATE AND ERROR CODES

PORTABLE BLU RAY PLAYER 

PANASONIC DMP-B100EB 

SERVICE MODE  FIRMWARE UPDATE AND ERROR CODES 

Service Mode
Information necessary for service can be displayed.
Service mode setting:
1. Turn the power off.
2. Press the [OPTION] + [PLAY] and [VOL DOWN] button simultaneously for five seconds.
3. It is displayed on LCD as [SERV]. : It is shown to have entered the service mode. ([PLEASE WAIT] is displayed previously according to the A/V mode.)

4. The command is transmitted by attached remote control. Method of making clear service mode : Press the power button (power off). The display of information to each command is as follows.
NOTE: Do not use it excluding the designated command.
Error Code Display
Last Error Code of U/F held by memory is displayed on FL. *Details are described in "Self-Diagnosis Functions"
Press [0] [1] in service mode.
ROM Version Display
Press [0] [2] in service mode.
The display contents are switched over every 5 seconds.
1. Region code
2. Main firm version
3. Timer firm version
4. Drive firm version
5. ROM correction version
6. BOO2 version
7. BOO3 version
Drive Check
Simple quality of BD drive
Press [0] [3] in service mode.
Laser Used Time Indication
Check laser used time (hours) of drive.
Press [4] [1] in service mode.
BD drive last error
BD drive error code display.
Press [4] [2] in service mode.
CEC (H) output check
Check of the CEC terminal high output of HDMI.
Press [5] [5] in service mode.
CEC (L) output check
Check of the CEC terminal low output of HDMI.
Press [5] [6] in service mode.
Delete the Laser Used Time
Laser used time information stored in the memory of the unit is deleted.
Press [9] [5] in service mode.
Delete the Last Drive Error
Laser Drive Error information stored on the BD Drive is deleted.
Press [9] [6] in service mode.
Delete the Error History
Error History information stored on the unit is deleted.
Press [9] [7] in service mode.
Initialization of Error code
Last Error Code information stored by timer is deleted. (Write in F00)
Press [9] [8] in service mode.
Initialization of the Service Mode
Last Drive Error, Error History and Error code information stored on the unit are initialized to factory setting.
Press [9] [9] in service mode.
Self-Diagnosis Functions
Self-Diagnosis Function provides information for errors to service personnel by “Self-Diagnosis Display” when any error has occurred.
U**, H** and F** are stored in memory and held.
You can check latest error code by transmitting [0] [1] of Remote Controller in Service Mode. In case of clear the self-diagnosis display, remove the battery pack and the AC adaptor from the main unit after the power of the main unit is turned off.
ERROR CODES
Error Code
Diagnosis contents
U580
Battery supply current abnormality
U581
Abnormal charge time on battery power
U582
Battery-powered temperature anomaly
U59
Abnormal inner temperature detected
U72
HDMI connection error (communication error)
U73
HDMI connection error (authentication error)
U76
Connection error
U77
Illegal disc error
U88
Restoration is operation. (When the disc is in the disc tray)
H19
No working Fun Motor
F00
No error information
F58
Drive hardware error
F74
HDMI Device Key Communication error
F75
HDMI Device Key Loading error

Cleaning of the Optical Pick-up

Adjustment Instruction when Exchange the Traverse or Main P.C.B. (Servo Adjustment)
(Preparation)
1. Install adjustment software "BD Drive Adjustment" of the pertinent model placed in the "TSN Website", therefore, access to "TSN Website" at "Support Information from NWBG/VDBG-AVC".
2. Prepare the SD Memory card, and then write the following data. (Write it after the SD Memory card formats with FAT/ FAT16 without fail.)
Condition of SD Memory Card
128MB - 2GB (SDHC Memory Card cannot be used)
a. 6a9b.bin
b. drv.bin
c. BD-P Update history.txt
3. Take notes of the number of fifteen digits of QR code label (label of the lower) pasted to bottom of the OPTICAL PICK-UP.

4. Prepare three test discs:
RFKZ0515: BD-ROM test disc (VFF0396),
RFKZ0514: DVD-RAM test disc (X5RAM-BPS),
RFKZ0516: CD-ROM test disc (CD-ROM-B01).
5. Prepare a new CD-R disc, and then make the disc for the upgrade of the latest firmware.
Upgrade procedure of firmware by disk making
# Step 1.
Choose the model that you are using and download the firmware.
# Step 2.
Please defrost the downloaded file.
# Step 3.
Prepare a CD-R disc, and write the above-mentioned file on
the CD-R disc, and then make the disc for the upgrade.
# Step 4.
Set the disc the made upgrade, and do the upgrade of the firmware.
Adjustment Procedure
1. Start “BDP Adjustment”.
2. Begin the adjustment of “Start”.
3. Select “DMP-B100”, and select “OK”.
4. Select “Utility”
5. Select “COM Setup”.
6. Select “COM1”, and select “OK”.
7. Select “Spec Setup”.
8. Select the new soft ware, and select “OK”.
(Make it to the latest software selecting “NEW”.)
9. Select “Exit”.
10. Select “Adjustment”.
11. Insert the SD DIAG Card.
12. Turn on the switch of serial cable (RFKZ0139), and select “OK”.
13. Connect the AC power supply code with the power supply outlet, and select “OK”.
14. The last repair date is displayed. Confirm and select “OK”.
15. Input the number of fifteen digits of QR code label (label of the lower) pasted to OPU assay of the traverse unit, and select "OK".
16. Take out the SD DIAG Card.
17. Detach the AC power supply code from the power supply outlet, and select “OK”.
18. Turn off the switch of serial cable (RFKZ0139).
19. Connect the AC power supply code with the power supply outlet, and select “OK”.
20. Adjust “DIAG” “SPEC” “LPC” by the automatic operation. (It takes a few minutes.)
21. Set the DVD-RAM test disc (X5RAM-BPS), and select “OK”.
22. Adjust “DISC” by the automatic operation.
23. Take out the DVD-RAM test disc (X5RAM-BPS).
24. Set the BD-ROM test disc (VFF0396), and select “OK”.
25. Take out the BD-ROM test disc (VFF0396), and select “OK”.
26. Detach the AC power supply code from the power supply outlet, and select “OK”.
27. Finish the servo adjustment. Select “Exit” and finish.
28. Detach the serial cable (RFKZ0139), and assemble the main body, and then confirm the sound with CD-ROM test disc (RFKZ0516).
29. Improve the version to the latest firmware, after traverse unit or main P.C.B. is exchanged.