SONY BDP-BX18 - BDP-S185 - BDP-S186 SERVICE MODE AND INITIALIZATION

SONY BDP-BX18 - BDP-S185 - BDP-S186 

BLU RAY PLAYER 

SERVICE  MODE AND INITIALIZATION

Enter Service Mode
OPTION 1
Disconnect the AC, and Push front panel key ([OPEN/CLOSE] + [PLAY] + [STOP]) and AC IN
The keys will be released if the screen in service mode is displayed on a monitor.
Control via Remote Controller
OPTION 2
Connect the set to AC, and wait initialization cycle complete . POWER ON SET INTO NORMAL MODE. WHEN CROSS MEDIA BAR APPEAR. Use Sony BDP remote controller, key in the following SIRCS code.
DISPLAY > 0 > 2 > 1 > SUBTITLE
While sending of SIRCS code, wait time between each key code could not send later then 3 second. If 3 second waiting is exceeded user have to re-key in the SIRCS code.
If SIRCS enter is successful, set will auto boot up. The screen of service mode is displayed on a monitor. Control via Remote Controller
Diag
The unit test of the device mounted on the MainBoard.
Display Error Log
Error log is displayed.
The displayed logs can be saved in a USB memory.
Factory Initialize
Return all of the player setting to their factory defaults.
Network
Confirm Wired Network connection.
Version Up
The set updates by Update DISC.
System Information
System information of the set is displayed.
The Information on a soft version and drive information, etc. is displayed.
EMC Test Mode
Not used.
Drive
Write Drive OP Data and check drive.
Service Mode Top Menu
It selects to each function from here. output HDMI/Component 480p forcibly.
Operation

1 > Select and Activate Diag Menu.
2 > Select and Activate Log Menu,
3 > Select and Activate Factory Initialize Menu.,[4] > Select and Activate Network Menu
5 > Select and Activate Version Up
DISC version Up Menu,
6 > Select and Activate System Information Menu.
7 > Select and Activate EMC Test Mode Menu. (not Used)
8 > Select and Activate Drive Menu.
9 > Select and Activate HDD mode. (not Used)
UP > Move Up cursor
DOWN > Move Down cursor
ENT > Activate the selected cursor.
INITIALIZING THE BLU RAY
Outline:
Return all of the player setting to their factory defaults.
select initialize.
Operation

When you return a set to the factory defaults, push [1] on this screen.
ENT > Start Factory Initialize
RET > Return to Service Top Menu.
RET > Return to Service Top Menu.
Please disconnect AC power supply, and connect AC again.
The operation of other service mode menu can be continued.
DRIVE TEST
Outline
Activate Drive test
Select Drive test category
Operation
LEFT/ RIGHT > Select Category
DOWN/ENT > Activate the selected Category.
RET > Return to Service Top Menu.
1 > Drive OP data Write
2 > Servo Parameter Check Menu (Not Used)
3 > Servo Signal Check Menu (Not Used)
4 > S-Curve Check Menu (Not Used)
5 > Readability Check Menu (Not Used)
6 > OP Position Check Menu (Not Used)
7 > OP Check Menu (Not Used)
8 > Load Eject Aging (Not Used)
9 > Spindle Control Check Menu (Not Used)
10 > FA Test Mode (Not Used)
To start OP data Write
Operation :
ENT > Start
Show OP data Write result
Operation :
NG - USB is not find
NG – File(Budata.txt) is not find
OK – OP data write
Drive Test:
For drive operating check. Service is only use Drive OP data write to re write OP data after change of new OPU
SONY BDP-BX18 - BDP-S185 - BDP-S186 OPTICAL PICKUP UNIT PART NUMBER  
KEM-470AAA/C2RP